SP5 Starter Motors
 
APPLICATION : This axial starter is designed for use on diesel engines upto 6 litres capacity.
 
RATINGS:
System voltage : 12 Volts
Thermal:
Operating temperature range : -5°C to 93°C
Power : 2.7KW
Lock torque : 3.8Kg.m. at 1400Amps. (max) and 5 volts.
Run torque : 1.6 Kg.m. at 700 Amps. (max) 8 volts and 1400 rpm.
Weight : 16kg (approx).
 
FEATURES:
Fixing : Fixing to be rigidly mounted in a spigot location (for flange mounting only) adjacent to the flywheel with SAE 3 flange, or fixing arrangement to meet customers requirement.
Pinion : Standard 9 Teeth 3 module, 14.5° angle. Alternative pinion forms to suit specific applications by arrangement.
Rotating : clockwise when viewed from drive end.
 
TERMINATIONS:
Stud terminations:
Main terminal : M10 X 1.5
Earth terminal : M6 X 1
Solenoid terminal : BBNG-1 - 12V switch.
Enclosures : Externally protected (except from bell housing) against water and oil spray.

 